NTV Series
3kVDC Isolated 1W Dual Output SM DC/DC Converters
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
Conditions
Flash tested for 1 minute
Viso= 1000VDC
Min.
3000
10
Typ.
Max.
Units
VDC
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Conditions
5V input types
12V input types
Min.
Typ.
115
120
Max.
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Speci?cation
Storage
Case temperature above ambient
Conditions
All output types
5V output types
All other output types
Min.
-40
-55
Typ.
33
25
Max.
85
125
Units
°C
Cooling
Free air convection
TEMPERATURE DERATING GRAPH
1.5
TOLERANCE ENVELOPE
+10%
o Line
1.0
85°C
+5%
V NOM
T y pic al L
ad
+2.5%
-2.5%
0.5
Safe Operating Area
-7.5%
0
-40
0 50 100
Ambient Temperature (°C)
150
10
25 50 75
Output Load Current (%)
100
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, ap-
plied for a speci?ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NTV series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no speci?c agency approvals, such as the NTV series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.
The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be
expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded
as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard
requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NTV series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We there-
fore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from speci?ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insula-
tion system of physical spacing or barriers.
MINIMUM LOAD
The minimum load to meet datasheet speci?cation is 10% of the full rated load across the speci?ed input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the speci?ed output voltage if the output load falls to less than 5%.
www.murata-ps.com/support
KDC_NTV.F01 Page 2 of 4
相关PDF资料
NVS01YG-M6 CONVERT DC/DC 5V OUT 6W SMD
OKI-78SR-3.3/1.5-W36-C CONV DC/DC 4.95W 36VIN 3.3VOUT
OKI-T/3-W32N-C CONV DC/DC 3A 24VIN NEG SMD
OKI-T/3-W40P-C CONV DC/DC 3A 15W 24VIN SMD
OKI-T/36W-W40P-C CONV DC/DC 36W 5-15V NEG ON/OFF
OKL-T/3-W12P-C CONV DC/DC 15W 12VIN 3AOUT SMD
OKL-T/3-W5N-C CONV DC/DC 9.9W 3A 5VIN SMD
OKL-T/6-W12N-C CONV DC/DC 30W 6A 12VIN SMD
相关代理商/技术参数
NTV0512MC-R 功能描述:DC/DC转换器 5V +/-12Vout +/-42mA 3kVDC Iso 1W SMT RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
NTV0512M-R 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog IC
NTV0515M 功能描述:DC/DC转换器 1W DUAL OUT 5-15V RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
NTV0515MC 功能描述:DC/DC转换器 5V +/-15Vout +/-33mA 3kVDC Iso 1W SMT RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
NTV0515MC-R 功能描述:DC/DC转换器 5V +/-15Vout +/-33mA 3kVDC Iso 1W SMT RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
NTV0515M-R 制造商:未知厂家 制造商全称:未知厂家 功能描述:Analog IC
NTV1205M 功能描述:DC/DC转换器 1W DUAL OUT 12-5V RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
NTV1205MC 功能描述:DC/DC转换器 12V+/-5Vout +/-100mA 3kVDC Iso 1W SMT RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸: